Iodide Half-Cell Ion Selective Electrode (ISE) HI4011
The HI4011 is a solid state, half-cell ion selective electrode (ISE) for the determination of iodide (I-) in solution. The silver iodide sensing pellet produces a potential change due to the iodide ion exchange between the inorganic pellet membrane and the sample. The internal sensing elements are housed within a durable epoxy body. The HI4011 is ideal for a variety of applications in food production and environmental monitoring.
- Solid state sensor
- Detection from 0.01 to 127,000 mg/L I-
- For use with HI5315 reference half-cell
Manufacturer | Hanna Instruments |
---|---|
Electrodes Parameters | Iodide |
Electrode Connection | BNC |
Hazardous | No |
Note | Ships with heat pack(s) during winter months. |
Type | solid state; half-cell |
Measurement Range | 1M to 1•10-7M 127000 to 0.01 mg/L (ppm) |
Optimum pH Range | 2 to 13 |
Temperature Range | 0 to 80°C |
Diameter | 12 mm |
Length | 120 mm |
Body Material | epoxy |
Cable | 1 m coaxial |
Common Applications | determination of free iodide ions in emulsified food samples (iodized table salt), plants and for titration |
Connection | BNC |
Warranty | 6 months |
The HI4011 iodide selective electrode is a potentiometric half-cell sensor housed within an epoxy body. The internal elements are isolated from the sample by a compressed silver iodide sensing membrane. This solid-state sensor requires a separate reference electrode to complete the measurement system.
Hanna’s solid-state half-cell ISEs are designed for use with the HI5315 reference half-cell. The reference half-cell features a cone style junction. The skirted cone geometry of the reference forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.
For the HI4011 to measure iodide accurately, it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the halide ionic strength adjuster (ISA) solution. The halide ISA ensures that the activity coefficient is constant so the concentration of free iodide ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The HI4011 iodide solid-state ISE can measure from 0.1µM (0.01 mg/L) to1M (127,000 mg/L).