Principles of Operation:
Fluid flowing through the unit causes the paddle wheel to spin. As the magnets embedded in the paddle spin past the sensor, electrical pulses are produced in which frequency is proportional to the flow rate. The revolutions per minute and the K-factor (number of pulses/Gallon) make it is possible to calculate the flow volume passing through the unit.
- Flow meters for liquid flow applications
- Jewel bearings allow for very low minimum flow rates
- Easy to install and operate
- Mounted horizontally or vertically
- Only one moving part
- Flow indication via transparent acrylic cover
- Versatile square wave signal
- Female NPT ports
- Multiparameter: Flow and temperature outputs. Platinum RTD option
- Polypropylene and chemically resistant PVDF models
SPECIFICATIONS:
- ACCURACY ±1% FS
- MAXIMUM TEMPERATURE 70° C (160° F)
- MAXIMUM PRESSURE 10 bar (150 psi)
- POWER 5 to 24 Vdc @ 2 mA
- OUTPUT SIGNAL NPN open collector (load 30 mA max)
DIMENSIONS 56H x 108L x 53D mm (2.2 x 4.25 x 2.2")Without RTD and Hall switch adapters. - CABLE 1.8 m (6') or 3.7m (12') optional
- RTD Platinum 0.00385 TCR, meetsEN 60751, Class B