Silver/Sulfide Half-Cell Ion Selective Electrode (ISE) HI4015
The HI4015 is a solid state, half-cell ion selective electrode (ISE) for the determination of silver (Ag+) or sulfide (S2-) in solution. The silver/silver sulfide sensing pellet produces a potential change due to the ion exchange between the inorganic pellet membrane and the sample. The internal sensing elements are housed within a durable epoxy body. The HI4015 is ideal for a variety of applications in water conditioning, environmental monitoring, and industrial processes.
- Silver detection from 0.11 to 107,900 mg/L Ag+
- Sulfide detection from 0.003 to 32,100 mg/L S2-
- For use with HI5315 reference half-cell
| Manufacturer | Hanna Instruments |
|---|---|
| Electrodes Parameters | Silver |
| Electrode Connection | BNC |
| Hazardous | Yes |
| Note | Ships with heat pack(s) during winter months. |
| Type | solid state; half-cell |
| Measurement Range | 1.0M to 1•10-6M 107900 to 0.11ppm (Ag+) 1.0M to 1•10-7M 32100 to 0.003 ppm (S2-) |
| Optimum pH Range | 2 to 8 (Ag+) 12 to 14 (S2-) |
| Temperature Range | 0 to 80°C |
| Diameter | 12 mm |
| Length | 120 mm |
| Body Material | epoxy |
| Cable | 1 m coaxial |
| Common Applications | used as an indicator for titrations using silver nitrate; for the determination of sulfide ions in waters, paper liquors, natural waters and soils. |
| Connection | BNC |
| Warranty | 6 months |
The HI4015 silver/sulfide selective electrode is a potentiometric half-cell sensor housed within an epoxy body. The internal elements are isolated from the sample by a compressed silver/silver sulfide sensing membrane. This solid-state sensor requires a separate reference electrode to complete the measurement system.
Hanna’s solid-state half-cell ISEs are designed for use with the HI5315 reference half-cell. The reference half-cell features a cone style junction. The skirted cone geometry of the reference forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.
Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The HI4015 silver/sulfide solid-state ISE can measure silver from 1µM (0.11 mg/L) to 1M (107,900 mg/L) and sulfide from 0.1µM (0.003 mg/L) to 1M (32,100 mg/L).